C00637 | resp. to new module in mxi2, E94aycen communication manual (ethernet) – Lenze E94AYCEN User Manual

Page 55

Advertising
background image

EDS94AYCEN EN 9.0 - 09/2012

L

55

E94AYCEN communication manual (Ethernet)

Parameter reference

Parameters of the standard device that are relevant to communication

C00637

Parameter | Name:

C00637 | Resp. to new module in MXI2

Data type: UNSIGNED_32

Index: 23939

d

= 5D83

h

Response if a new module has been plugged into module slot 2 of the standard device.
Selection list

(Lenze setting printed in bold)

1 Fault
6 Information
5 Warning
4 Warning Locked
3 Quick stop by trouble
0 No Response

;

Read access ; Write access … CINH … PLC STOP … No transfer

Note!

The standard device codes C01501 and C01502 have no effect when using the

E94AYCEN (Ethernet) communication module.