EDS94AYCEN EN 9.0 - 09/2012

L

59

E94AYCEN communication manual (Ethernet)

Parameter reference

Parameters of the communication module for slot MXI1

C13007

C13008

Parameter | Name:

C13007 | Resolved Subnetmask

Data type: UNSIGNED_8

Index: 11568

d

= 2D30

h

The subnet mask indicates which part of the IP address is evaluated as Net-ID and which part as Host-ID.

• The subnet mask consists of four numbers from 0 to 255 which can be set in the four subcodes.



Subnet mask ( 31)

Display range

(min. value | unit | max. value)

0

255

Subcodes

Info

C13007/1

Subnet mask

• Sequence: "[1].[2].[3].[4]"

C13007/2
C13007/3
C13007/4

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C13008 | Resolved Gateway-Address

Data type: UNSIGNED_8

Index: 11567

d

= 2D2F

h

The gateway address is required if the Servo Drive 9400 is not located in the same subnetwork as the PC.

• The gateway address consists of four numbers from 0 to 255 which can be set in the four subcodes.



Gateway address ( 32)

Display range

(min. value | unit | max. value)

0

255

Subcodes

Info

C13008/1

Gateway address

• Sequence: "[1].[2].[3].[4]"

C13008/2
C13008/3
C13008/4

;

Read access … Write access … CINH … PLC STOP … No transfer