Parameter data transfer

Transmission abort

42

L

EDS94AYCEN EN 9.0 - 09/2012

Assignment of the User data area with parameter values of different data lengths
Depending on the data format, the parameter value occupies 1 to 8 bytes. Data are stored

in little-endian format, i.e. first the low byte or low word, then the high byte or high word:

7.5

Transmission abort

The transmission is either aborted by the client or the server of a parameter data telegram.

The message is aborted without confirmation. If the SDO client awaits the message to be

confirmed, it will receive an abort message instead.

Data length

Data area P3

Data area P4

Byte 1

Byte 2

Byte 3

Byte 4

Byte 1

Byte 2

Byte 3

Byte 4

1 byte

Value

00

00

00

00

00

00

00

2 bytes

Low byte

High byte

00

00

00

00

00

00

Value

4 bytes

Double word

00

00

00

00

Low word

High word

Low byte

High byte

Low byte

High byte

Value

8 bytes

Lower-order double word

Higher-order double word

Low word

High word

Low word

High word

Low byte

High byte

Low byte

High byte

Low byte

High byte

Low byte

High byte

Value