E94aycen communication manual (ethernet), Parameter data transfer telegram examples – Lenze E94AYCEN User Manual
Page 46
E94AYCEN communication manual (Ethernet)
Parameter data transfer
Telegram examples
46
L
EDS94AYCEN EN 9.0 - 09/2012
Response
GCI message qualifier (GMQ) = 0x80 = 10000000B = "Response"
GCI header
GMT
GSV
GMQ
GTI
SIZE
SIZE
res
res
0x01
0x82
0x80
0x00
0x14
0x00
0x00
0x00
Fixed
Reading
parameters
Response
Transactions ID
Length of the user data = 20 bytes
Reserved
User data area P0
Byte 1
Byte 2
Byte 3
Byte 4
Reserved
Reserved
Data type
Reserved
0x00
0x00
0x03
0x00
INTEGER_32
User data area P1
User data area P2
Byte 1
Byte 2
Byte 3
Byte 4
Byte 1
Byte 2
Byte 3
Byte 4
Code
Reserved
Reserved
Subcode
Reserved
Reserved
0x3D
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Code = 61 = 0x003D
Subcode = 0
User data area P3
User data area P4
Byte 1
Byte 2
Byte 3
Byte 4
Byte 1
Byte 2
Byte 3
Byte 4
Parameter value of data type INTEGER_32
Reserved
0x00
0x00
0x00
0x2B
0x00
0x00
0x00
0x00
Read value = 0x0000002B = 43 [°C]