E94aycen communication manual (ethernet), Parameter data transfer telegram examples – Lenze E94AYCEN User Manual

Page 46

Advertising
background image

E94AYCEN communication manual (Ethernet)

Parameter data transfer

Telegram examples

46

L

EDS94AYCEN EN 9.0 - 09/2012

Response
GCI message qualifier (GMQ) = 0x80 = 10000000B = "Response"

GCI header

GMT

GSV

GMQ

GTI

SIZE

SIZE

res

res

0x01

0x82

0x80

0x00

0x14

0x00

0x00

0x00

Fixed

Reading

parameters

Response

Transactions ID

Length of the user data = 20 bytes

Reserved

User data area P0

Byte 1

Byte 2

Byte 3

Byte 4

Reserved

Reserved

Data type

Reserved

0x00

0x00

0x03

0x00

INTEGER_32

User data area P1

User data area P2

Byte 1

Byte 2

Byte 3

Byte 4

Byte 1

Byte 2

Byte 3

Byte 4

Code

Reserved

Reserved

Subcode

Reserved

Reserved

0x3D

0x00

0x00

0x00

0x00

0x00

0x00

0x00

Code = 61 = 0x003D

Subcode = 0

User data area P3

User data area P4

Byte 1

Byte 2

Byte 3

Byte 4

Byte 1

Byte 2

Byte 3

Byte 4

Parameter value of data type INTEGER_32

Reserved

0x00

0x00

0x00

0x2B

0x00

0x00

0x00

0x00

Read value = 0x0000002B = 43 [°C]