Appendix

Codes

11

l

59

EDSMF2192IB EN 3.1

Parameter

C1825

Name

AIF output double words (from the standard device)

Data type: UINT32

Index: 22750

dec

= 58DE

hex

Display of the process output data

Display area

(min. value | unit | max. value)

0x00000000

0xFFFFFFFF

Subcodes

Information

C1825/1

...

C1825/n

Parameter

C1830

Name

Bus status

Data type: FIX32

Index: 22745

dec

= 58D9

hex

Bit−coded display of the current bus status

^ 40
Display area

(min. value | unit | max. value)

0x00000000

0xFFFFFFFF

Bits

(read only)

Information

Bit 0 EtherCAT bus status in accordance

with CiA DS301

0: Unknown
1: Init
2: Pre−operational
3: Bootstrap
4: Safe−operational
8: Operational

...

Bit 7

Bit 8 Not assigned

...

Bit 12

Bit 13 SYNC_bProcessDataExpected

New process data were expected during the
application cycle.

Bit 14 SYNC_bProcessDataInvalid

New/last process data are invalid.

l

Checksum error

l

No telegram received

Bit 15 EtherCAT error flag

Parameter

C1850

Name

Station alias address

Data type: FIX32

Index: 22725

dec

= 58C5

hex

Specification of the station address if the master is used to address the alias

l

0: no alias address

l

65535: Alias address preselection in the slave

Setting range

(min. value | unit | max. value)

Lenze setting

0

65535 0

Parameter

C1882

Name

Response when exiting "Operational"

Data type: FIX32

Index: 22693

dec

= 58A5

hex

Adjustable response for the process data monitoring

Selection list

(Lenze setting printed in bold)

Information

0 No response

1 Error (TRIP)

2 Controller inhibit (CINH)

3 Quick stop (QSP)