Commissioning

Setting node address and baud rate

EDK82ZAFUC−001 DE/EN/FR 4.0

68

l

H2_set_node_addr_baud−Ueb−rate Hinweis

Baud rate setting

ON

1

6

2

7

4

3

8

5

9 10

ON

OFF

Fig. 2

Baud rate setting

)

Note!

The baud rate must be set to the same value for all controllers and the master
computer.

Baud rate [kbps]

S8

S9

S10

10

ON

ON

OFF

20

ON

OFF

ON

50

OFF

ON

ON

125

OFF

ON

OFF

250

OFF

OFF

ON

500

OFF

OFF

OFF

1000

ON

OFF

OFF

Automatic recognition

ON

ON

ON

Automatic recognition of the baud rate

)

Note!

The baud rate can only be recognised automatically if other nodes are already
sending telegrams via the CAN bus without errors:

ƒ

After switch−on or "Reset Node" the function module searches for the
correct baud rate by analysing the telegrams sent by the other nodes.

ƒ

If the correct baud rate is recognised, it is accepted by the function module.