Diagnostics – Lenze E82ZAFUC001 User Manual
Page 71
![background image](/manuals/565938/71/background.png)
Diagnostics
LED status displays
EDK82ZAFUC−001 DE/EN/FR 4.0
71
l
H1_Diagnose−st_00tu0
LED
Description
Pos.
Colour / status
1
off
Connection to master not established.
green
CANopen status ("
S
")
red
CANopen fault ("
F
")
red
S
: bus off
blinking fast (jittering)
Automatic baud rate recognition is active.
blinking (green) every 0.2 s
S
: pre−operational,
F
: none
blinking (green) every 0.2 s
blinking (red) 1 x, 1 s off
S
: pre−operational,
F
: warning limit reached
blinking (green) every 0.2 s
blinking (red) 2 x, 1 s off
S
: pre−operational,
F
: node guard event
on (green)
S
: operational,
F
: none
on (green)
blinking (red) 1 x, 1 s off
S
: operational,
F
: warning limit reached
on (green)
blinking red 2 x, 1 s off
S
: operational,
F
: node guard event
on (green)
3 x blinking red, 1 s off
S
: operational,
F
: sync message error
blinking (green) once per
second
S
: stopped,
F
: none
blinking (green) once per
second
blinking (red) 1 x, 1 s off
S
: stopped,
F
: warning limit reached
blinking (green) once per
second
blinking red 2 x, 1 s off
S
: stopped,
F
: node guard event