Electrical installation

Terminal strips on the top of the device

6

l

60

EDK10200EV3 DE/EN/FR 7.1

Terminal Use

Level

Data

Voltage
supply

X1/

^24

0 V of supply voltage,
ground for digital inputs
and outputs

X1/+24

Supply voltage

+18 VDC ... 30 VDC

X1/+O24 Supply voltage for digital

outputs

+18 VDC ... 30 VDC

Digital
inputs

X3/I1

Freely assignable input 1

HIGH active
LOW: 0 V ... +4 V
HIGH: +13 V ... +30 V

Input current: 8 mA at 24 V
Reading and processing the
inputs: shortest reading cycle:
1 ms (depending on the site
where the process map is
generated)

X3/I8

Freely assignable input 8

Digital
outputs

X2/O1

Freely assignable output
1

HIGH active
LOW: 0 V ... +4 V
HIGH: +13 V ... +30 V

Load capacity: max. 1 A per
output
Updating the outputs:
shortest update cycle is 1 ms
(depending on the site where
the process map is generated)

X2/O4

Freely assignable output
4

Advertising