Troubleshooting and fault elimination

System error messages

8

l

71

EDK10200EV3 DE/EN/FR 7.1

Remedy

Cause

Fault

Display

PC

1)

Keypad

H05

a

105

Internal fault

Contact Lenze

H08

a

108

Error when
configuring the
extension board

Extension board has not
been plugged−on correctly
or not supported by the
program

l

Check plug connection

l

Check if the extension board
is supported by the operating
system version

per

a

74

Error in program
flow

An error has been
detected in the program
flow.

Send Drive PLC with data set (to
floppy disk) to Lenze

pi

a

79

Initialisation error
during parameter
set transfer

l

During the parameter
set transfer to the
Drive PLC an error has
been detected

l

Wrong parameter set
for Drive PLC

Correct parameter set

Pr0

a

75

Internal fault

Contact Lenze

Pr1

a

72

PAR1 incorrectly
transferred via
keypad/PC

PAR1 is defective

Repeat data transfer or load
Lenze setting

Pr5

a

79

Internal fault

Save cyclic parameter set

Do not execute "Save cyclic
parameter set" since this
damages the EEPROM

1)

LECOM error number

)

Note!

Detailed information on the system error messages of the Drive PLC can be
found in the PDF manual "Drive PLC" (chapter Appendix: System error
messages)