System error messages, Troubleshooting and fault elimination – Lenze EPL1020x−EI User Manual

Page 70

Advertising
background image

Troubleshooting and fault elimination

System error messages

8

l

70

EDK10200EV3 DE/EN/FR 7.1

System error messages

Display

Fault

Cause

Remedy

Keypad

PC

1)

noer

a

0

No fault

ccr

a

71

System fault

Heavy interference
injections on the control
cables

Install shielded control cable

Earth loops in wiring

ce0

a

61

Communication
error at AIF

Transmission of control
commands via AIF is faulty

Firmly insert the communication
module in the diagnosis
terminal

ce1

a

62

Communication
error at
CAN−IN1 with sync
control

CAN−IN1 object receives
faulty data or
communication is
interrupted

l

Check plug connection of bus
module

ó FIF

l

Check transmitter

l

Possibly increase monitoring
time in C0357/1

ce2

a

63

Communication
error at
CAN−IN2

CAN−IN2 object receives
faulty data or
communication is
interrupted

l

Check plug connection of bus
module

ó FIF

l

Check transmitter

l

Possibly increase monitoring
time in C0357/2

ce3

a

64

Communication
error at
CAN−IN3 with event
or time control

CAN−IN3 object receives
faulty data or
communication is
interrupted

l

Check plug connection of bus
module

ó FIF

l

Check transmitter

l

Possibly increase monitoring
time in C0357/3

ce4

a

65

Bus−off
(many
communication
errors occurred)

Drive PLC received too
many faulty messages via
system bus and decoupled
itself from the bus

l

Check whether bus
termination is present

l

Shield connection of cables

l

Check PE connection

l

Check bus load, reduce baud
rate, if necessary

EEr

a

91

External fault (TRIP
set)

A digital signal assigned
with the TRIP set function
was activated

Check external encoder

Advertising