7 commissioning, Before switching on, Commissioning – Lenze EPL1020x−EI User Manual
Page 65: Stop
Advertising
Commissioning
Before switching on
7
l
65
EDK10200EV3 DE/EN/FR 7.1
7
Commissioning
Before switching on
(
Stop!
Make the connection between the PC and Drive PLC and the PC system bus
module ONLY when the equipment is switched off!
0
1
2
3
l
Drive PLC
Developer
Studio
GND
HI
X5
+18 … 30 VDC / 0 V
LOW
120
W
plc017
0
PC
1
Drive PLC
2
Bus terminating resistor 120
W
3
PC system bus module