Electrical installation – Lenze ECSDExxx User Manual

Page 103

Advertising
background image

Electrical installation

Control terminals

4

l

103

EDKCSDE040 DE/EN/FR 4.0

Assignment of the plug connectors

Terminal strip X6

View

Terminal

Function

Electrical data

T1

DO1

DI2

DI1

T2

D24

GND

+24

X6/+24

Low−voltage supply of control
electronics

20 ... 30 V DC, 0.5 A (max. 1 A)
for 24 V starting current:
max. 2 A for 50 ms

X6/GND

Reference potential low−voltage
supply

X6/T1

Thermostat contact 1

X6/T2

Thermostat contact 2

X6/D24

Low−voltage supply X6/DO1
(digital output 1)

18 ... 30 V DC

X6/DO1

Digital output 1
(for central controller enable
signal to connected axis
modules)

24 V DC, 0.7 A (max. 1.4 A)
short−circuit−proof

X6/DI1

Digital input 1
(for power supply enable/charge
of the DC bus)

LOW:
−3 ... +5 V;
−3 ... +1.5 mA
HIGH:
+15 ... +30 V;
+2 ... +15 mA
Input current at 24 V DC:
8 mA per input

X6/DI2

Digital input 2
(for central controller enable
signal to connected modules;
available at output X6/DO1)

Cable cross−sections and screw−tightening torques

Cable type

Wire end ferrule

Cable cross−section

Tightening torque

Stripping length

Flexible

Without wire end
ferrule

0.08 ... 1.5 mm

2

(AWG 28 ... 16)

0.22 ... 0.25 Nm

(1.95 ... 2.2 lb−in)

5 mm for screw
connection

9 mm for spring
connection

With insulated wire
end ferrule

0.25 ... 0.5 mm

2

(AWG 22 ... 20)

We recommend to use control cables with a cable cross−section of 0.25 mm

2

.