Lenze ECSDExxx User Manual
Page 93
![background image](/manuals/566099/93/background.png)
Electrical installation
Power terminals
Connection plan for mimimum wiring with internal brake resistor
l
93
EDKCSDE040 DE/EN/FR 4.0
4.3.3
Connection plan for mimimum wiring with internal brake resistor
(
Stop!
Always operate the ECS power supply modules with a brake resistor
(internal/external).
The ECS power supply modules in the standard built−in unit and push−through
design (ECSEE / ECSDE) are provided with a device−internal brake resistor.
In order to use the internal brake resistor (Rb), carry out the following wiring:
ƒ
Bridge between the terminals X22/+UG and X22/BR0 (CR)
Current flow from +UG via the internal brake resistor (Rb) and the brake
transistor to −UG.
ƒ
Bridge between the terminals X6/T1 and X6/T2 (CR)
Deactivate the temperature monitoring of the non−existing external brake
resistor.