Lenze ECSDExxx User Manual

Page 93

Advertising
background image

Electrical installation

Power terminals

Connection plan for mimimum wiring with internal brake resistor

4

l

93

EDKCSDE040 DE/EN/FR 4.0

4.3.3

Connection plan for mimimum wiring with internal brake resistor

(

Stop!

Always operate the ECS power supply modules with a brake resistor
(internal/external).

The ECS power supply modules in the standard built−in unit and push−through
design (ECSEE / ECSDE) are provided with a device−internal brake resistor.
In order to use the internal brake resistor (Rb), carry out the following wiring:

ƒ

Bridge between the terminals X22/+UG and X22/BR0 (CR)
Current flow from +UG via the internal brake resistor (Rb) and the brake
transistor to −UG.

ƒ

Bridge between the terminals X6/T1 and X6/T2 (CR)
Deactivate the temperature monitoring of the non−existing external brake
resistor.