EDKCSDE040 DE/EN/FR 4.0

Scope of supply

Position

Description

Number

0

Power supply module ECSDExxx

1

2

Accessory kit with attachment material

1

Mounting instructions

1

Drilling jig

1

)

Note!

The ECSZE000X0B connector set must be ordered separately.

Connections and interfaces

Position

Description

Detailed

information

X22

Connections

l

External brake resistor

l

DC−bus voltage

l

PE

^

91

1

LEDs: Status and fault display

X1

Automation interface (AIF) for

l

Communication module

l

Operating module (XT keypad)

^

105

X2

PE connection AIF

X3

Not assigned

X4

CAN connection

l

System bus (CAN)

l

Interface for
– master control and other modules
– PC/HMI for parameterisation and diagnostics

^

106

X6

Connections

l

Low−voltage supply

l

Digital inputs and outputs

l

Thermostat contacts

^

104

S1

DIP switch

l

CAN node address (device address in the CAN network)

l

CAN baud rate

X21

Mains connection

^

88

Status displays

LED

Description

Red

Green

Off

On

Power supply module is enabled, no fault

Off

Blinking

Power supply module is inhibited (CINH), switch−on inhibit

Blinking, 1 Hz

Off

Fault / error (TRIP) / short−circuit braking error (KSB−TRIP) is active

Blinking, 3 Hz

Off

Message active

Blinking, 1 Hz

Blinking

Warning active with inhibited module

Blinking, 1 Hz

On

Warning active with enabled module

Advertising