Technical data – Lenze 8210 series User Manual
Page 13
Technical Data
UONu_^MPMQ
3-3
L
8214
8213
8212
8211
Type
150 % overload
EVF8214-E
EVF8213-E
EVF8212-E
EVF8211-E
Order no.
Motor voltage
3)
V
motor
[V]
0 - 3 × V
mains
/ 0Hz
¼ 50Hz, if required up to 480Hz
Power loss (operation with I
Nx
)
P
loss
[W]
55
75
90
100
Power reduction
[%/K]
[%/m]
40
°C < T
amb
< 50
°C: 2.5%/K
1000 m a.m.s.l < h ≤ 4000 m a.m.s.l: 5%/1000 m
Field
f
Resolution
Absolute
0.02 Hz
Field
frequency Digital setpoint
selection
Accuracy
0.05 Hz
Analog setpoint
l ti
Linearity
0.5 % (max. selected signal level: 5 V or 10 V)
Analog setpoint
selection
Temperature
sensitivity
0
¼ 40 °C: +0.4 %
Offset
0 %
Weight
m [kg]
2.2
2.2
2.2
2.2
Printed in bold Data for the operation with factory setting and a chopper frequency of 8 kHz.
1)
This power can be additionally obtained when operating a matching motor
2)
The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned here
and 2 minutes base load with 75% I
Nx
.
3)
With mains choke/mains filter: max. output voltage = approx. 96 % of the mains voltage
*
Chopper frequency of the inverter
Show/Hide Bookmarks