Commissioning – Lenze 8210 series User Manual

Page 43

Advertising
background image

Commissioning

UONu_^MPMQ

5-7

L

Help for decision

Motor cable*

screened 50 m

unscreened 100 m

screened > 50 m

unscreened > 100 m

C014

Single drives

recommended alternatively recommended alternatively

With constant load

-4-

-2-

-2-

-

With changing loads

-4-

-2-

-2-

-

With heavy start conditions

-4-

-2-

-2-

-

High-dynamic positioning and feed drives

-2-

-

-2-

-

Lifts and hoists

-4-

-2-/-4-

-2-

-

Pumps and fan drives

-3-

-2-

-3-

-2-

Three-phase reluctance motors

-2-

-

-2-

-

Three-phase sliding rotor motors

-2-

-

-2-

-

Three phase motors with assigned

frequency-voltage characteristic

-2-

-

-2-

-

Group drives (depending on the resulting

motor-cable length)

д

кЙл

= б

 ⋅ Eд

N

+ ä

O

+  + д

б

F

Similar motors and loads

-4-

-2-

-2-

-

Different motors and/or changing loads

-2-

-

-2-

*

8211: screened ≤ 15 m, unscreened ≤ 30 m

8212: screened ≤ 25 m, unscreened ≤ 50 m