Configuration

7-4

UONu_^MPMQ

L

Code

IMPORTANT

Possible settings

Name

Code

IMPORTANT

Info

Selection

Lenze

Name

C007

*

Terminal

configuration

-0-

E4

E3

E2

E1

-0- CW/CCWDC brakeJOG1/2/3
-1- CW/CCWPAR

JOG1/2/3

-2- CW/CCWQSP

JOG1/2/3

-3- CW/CCWPAR

DC brake

JOG1

-4- CW/CCWQSP

PAR

JOG1

-5- CW/CCWDC brake Trip set

JOG1

-6- CW/CCWPAR

Trip set

JOG1

-7- CW/CCWPAR

DC brake Trip set

-8- CW/CCWQSP

PAR

Trip set

-9- CW/CCWQSP

Trip set

JOG1

-10- CW/CCWTrip set

UP

DOWN

-11- CW/CCWDC brake UP

DOWN

-12- CW/CCWPAR

UP

DOWN

-13- CW/CCWQSP

UP

DOWN

-14- CCW/QSPCW/QSPDC brake

JOG1

-15- CCW/QSPCW/QSP PAR

JOG1

-16- CCW/QSPCW/QSPJOG1/2/3
-17- CCW/QSPCW/QSPPAR

DC brake

-18- CCW/QSPCW/QSP PAR

Trip set

-19- CCW/QSPCW/QSPDC brake Trip set
-20- CCW/QSPCW/QSP Trip set

JOG1

-21- CCW/QSPCW/QSP UP

DOWN

-22- CCW/QSPCW/QSP UP

JOG1

D

CW =

CW rotation

D

CCW =

CCW

rotation

D

DC brake =

DC injection

brake

D

PAR =

Change of

parameter

sets

D

JOG =

JOG

frequency

D

QSP =

Quick stop

D

Trip-Set =

External fault

D

UP/DOWN =

Motor

potentiometer

functions

C008

¿

Function relay K1

-1-

-0- Ready for operation
-1- TRIP fault message
-2- Motor is running
-3- Motor is running / CW rotation
-4- Motor is running / CCW rotation
-5- Field frequency f

d

= 0

-6- f

dset

reached

-7- Q

min

reached

-8- I

max

reached

-9- Overtemperature (

J

max

-10

°C)

-10- TRIP or Q

min

or IMP

C009

*

Device address

1

1

{1}

99

Only for LECOM

applications

C010 Minimum field

frequency

0.0

0.0

{0.1Hz}

480.0

C011 Maximum field

frequency

820X 50.0

30.0

{0.1Hz}

480.0

821X 50.0

7.5

{0.1Hz}

480.0

30.0

{0.1Hz}

480.0

(Software

2x)
(Software

1x)

822X/824X 50.0

7.5

{0.1Hz}

480.0