Configuration

UONu_^MPMQ

7-5

L

Code

IMPORTANT

Possible settings

Name

Code

IMPORTANT

Info

Selection

Lenze

Name

C012 Acceleration time

5.0

0.0

{0.1s}

999.0

C013 Deceleration time

5.0

0.0

{0.1s}

999.0

C014

¿

Operating mode

820X

-0-

-0- Linear characteristic V~f

d

with auto

boost

-1- Square characteristic V~f

d

2

with

auto boost

-2- Linear characteristic V~f

d

with

constant V

min

boost

-3- Square characteristic V~f

d

2

with

constant V

min

boost

821X/822X/

824X

-4-

-4- Motor-current control

C015 V/f-rated

frequency

820X 50.0

30.0

{0.1Hz}

960.0

821X 50.0

7.5

{0.1Hz}

960.0

30.0

{0.1Hz}

960.0

(Software

2x)
(Software

1x)

822X/824X 50.0

7.5

{0.1Hz}

960.0

C016 V

min

setting

C0 6

820X

*

0

{1 %}

40

* depends on

the unit

821X/822X/

824X

0

0

{1 %}

40

C017 Threshold Q

min

0.0

0.0

{0.1Hz}

480.0

C018

¿

Chopper

frequency

¿

821X/822X/824X

-1-

-0- 4 kHz
-1- 8 kHz
-2- 12 kHz
-3- 16 kHz
-4- 12 kHz noise optimized
-5- 16 kHz noise optimized

C019 Threshold auto

DC brake

821X/822X/824X

0.1

0.1

{0.1Hz}

5.0