4.Set slip compensation

(C021)

Rough setting by means of the motor data:

4.Set slip compensation

(C021):

л =

е

клуе

− е

к

е

клуе

⋅ NMMB

е

клуе

=

С

Зк

⋅ SM

é

s

Slip constant (C021)

n

rsyn

synchronous motor speed [min

-1

]

n

r

rated speed to motor nameplate [min

-1

]

f

dr

rated frequency to motor nameplate [Hz]

p

Number of pole pairs

Precise setting:
Change C021 under constant load until the speed is near the synchronous speed.
If C021 is set to too high values, the drive may become instable (overcompensation).

Important

D

The change from V/f-characteristic control to motor-current control should only be

carried out when the controller is inhibited.

D

The idle current of the motor (magnetizing current) must not exceed the rated

current of the controller.

D

With very small friction values it is possible that an angle offset of up to 180

°

occurs when enabling the controller.