background image

Technical Data

UONu_^MPMQ

3-5

L

8218

8217

8216

8215

Type

150 % overload

EVF8218-E

EVF8217-E

EVF8216-E

EVF8215-E

Order no.

8218-V003

8217-V003

8216-V003

8215-V003

Type

Variant ”Cold

Plate”

EVF8218-C-

V003

EVF8217-C-

V003

EVF8216-C-

V003

EVF8215-C-

V003

Order no.

Variant ”Cold

Plate”

Motor voltage

3)

V

motor

[V]

0 - 3 × V

mains

/ 0Hz

¼ 50Hz, if required up to 480Hz

Power loss (operation with I

Nx

)

P

loss

[W]

150

200

280

400

Power reduction

[%/K]

[%/m]

40

°C < T

amb

< 50

°C: 2.5%/K

1000 m a.m.s.l < h ≤ 4000 m a.m.s.l: 5%/1000 m

Field

f

Resolution

absolute

0.02 Hz

Field

frequency Digital setpoint

selection

Accuracy

0.05 Hz

Analog setpoint

l ti

Linearity

0.5 % (max. selected signal level: 5 V or 10 V)

Analog setpoint

selection

Temperature

sensitivity

0

¼ 40 °C: +0.4 %

Offset

0 %

Weight
”Cold Plate” without heat sink
”Cold Plate” with heat sink

m [kg]

5.3
2.8

20.8

5.3
2.8

20.8

5.3
2.8

20.8

5.3
2.8

20.8

Printed in bold Data for the operation with factory setting and a chopper frequency of 8 kHz.

1)

This power can be additionally obtained when operating a matching motor

2)

The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned here
and 2 minutes base load with 75% I

Nx

.

3)

With mains choke/mains filter: max. output voltage = approx. 96 % of the mains voltage

*

Chopper frequency of the inverter