Appendix, Application example – Lenze EPM−H606 User Manual

Page 105

Advertising
background image

Appendix

Application example

EPM−H605 with safety PLC and EVS 93xx − ES V004 servo inverter

10

l

105

EDBPM−H605 DE/EN/FR 7.2

10

Appendix

10.1

Application example

10.1.1

EPM−H605 with safety PLC and EVS 93xx − ES V004 servo inverter

ƒ

The safe PLC takes over the entire drive control.

ƒ

The safe sensor technology is supplied by the clock outputs of the safe
PLC and is applied to the safe digital inputs of the PLC.

ƒ

Safety relay K

SR

and mains contactor K10 are used to safely disconnect

the motor torque.

ƒ

Two proximity switches and a safe evaluator are used to safely monitor
the speed.

ƒ

Operating mode "manual" is used to monitor a reduced speed. Keep the
confirmation key pressed to enable the motion process.

ƒ

The PLC uses a safe output to change the speed limit of the speed
monitor.

ƒ

The speed monitor switches off its outputs when the limit speed is
exceeded.

Advertising
This manual is related to the following products: