Epm-h605 operating unit, Epm−h605 operating unit, Electrical installation – Lenze EPM−H606 User Manual
Page 84: Danger
![background image](/manuals/566238/84/background.png)
Electrical installation
Operating and display elements
EPM−H605 operating unit
l
84
EDBPM−H605 DE/EN/FR 7.2
5.5.1
EPM−H605 operating unit
}
Danger!
The force−opening switching contacts of the stop key with stop
functionality must be interconnected so that they meet the safety
category in accordance with EN 954−1, which has been determined
on the basis of the risk analysis of the machine in accordance with
EN 1050.
C1
C2
NO1
NO2
NC1
NC2
0
1
2
3
F9
F7
F8
F4
F5
F2
F3
F1
F10
F6
02
3
1
WHBK
PKBN
GYBN
WHBU
BNRD
BNBU
YEBN
VT
BNGN
WHGN
WHPK
GYPK
RDBU
GY
BN
h605_010
Fig. 5−6
Control and signal elements of the EPM−H605 operating unit
0
Stop key
C
Common
1
Confirmation key (rear side of operating unit) NC
Normally closed
(NC contact)
2
Key, black
NO
Normally open
(NO contact)
3
Illuminated key, white
)
Note!
ƒ
Use the keys NO1/NC1/C1 as NC contact or NO contact only.
ƒ
Confirmation key and stop key with stop functionality cannot be
influenced by the HMI project.