Step 5, Magna-loc, Installation of panel – Metal Sales Magna-Loc Installation User Manual

Page 47

Advertising
background image

© Metal Sales Manufacturing Corporation / Subject to change without notice 6/12

47

MAGNA-LOC

Magna-Loc Eave Panel

Cee Clamp

Magna-Loc

Peak Panel

Pull up center of panel

Endlap Purlin

Endlap

Pad

Note: It is critical that purlins at the ridge and endlap be exactly located as detailed on erection

drawings in order for panels to have adequate movement due to thermal expansion and contraction.

Panels with endlaps must be fixed at the eave and endlap splices are to be installed inline along the

same purlin. The following procedures also apply to panel runs with multiple laps.

ENDLAPPING OF PANEL

Endlap Purlins

Peak

Eave

1

2 4 6 8

3 5 7

In-line

Endlapping

8"

Endlap

Purlin

Magna-Loc

Panel

INSTALLING

PANEL CLIP

STEP

5

Magna-Loc Peak Panel

End of factory notch

Magna-Loc

Eave Panel

Endlap Pad

Endlap Purlin

INSTALLATION OF PANEL (

cont

.)

Steps:

1. The eave panel when installed should measure 8" from the web of the endlap purlin to the end of the eave panel. This

dimension must be verified. If the panel extends past the web of the endlap purlin by 8", verify that the eave overhang

dimension is correct.

2. The male and female legs of the high end of the eave panel are factory notched 2" to allow the peak panel to nest inside

the eave panel.

3. Slide Back-up Channel under panel in center of endlap and cee clamp to panel to hold in place for attachment.

4. Apply Endlap Pad on the notched end of the eave panel down male leg, across panel flat, and up the female leg ½" to ¾"

from the end of the panel.

5. Lap the female leg of the peak panel into the female leg of the eave panel lapping the proper 2".

6. Hold the flat of the peak panel up and nest the male legs together.