Magna-loc, Endwall w/ wall panel – Metal Sales Magna-Loc Installation User Manual

Page 64

Advertising
background image

© Metal Sales Manufacturing Corporation / Subject to change without notice 6/12

MAGNA-LOC

64

eNdwALL w/ wALL pANeL

INstALLAtION NOtes

1. Once panels have been installed, slide Back-Up Channel under upper edge of panels. Position Back-Up Channel to allow

for proper installation of endwall assembly. Use C-clamps to hold Back-Up Channel in place.

2. Apply a row of Double Bead Tape Sealant across panel, up and over all ribs approximately 6"-8" from panel end.

3. Install Magna-Loc End Dams over Tape Sealant. Before continuing make sure End Dam placement will accommodate

SSR High Side Pitch Break.

4. Once closure is set in Tape Sealant, fasten through End Dam, Tape Sealant, Magna-Loc panel, and into Back-Up Channel

with (5) #12-14 x 1" SD N/W per panel. C-clamps may be removed once closures have been fastened.

5. Once all End Dams have been installed, place a row of Double Bead Tape Sealant across top of End Dams. Tube Sealant

must be used to fill any and all gaps left around End Dams.

6. Install SSR High Side Pitch Break and secure to top leg of End Dams with ¼"-14 x

7

/

8

" Stitch XL at the spacing shown

above and to parapet wall with appropriate fastener, 12"o.c.

7. Install Counter Flashing, Reglet, or wall panel and fasten to parapet wall with appropriate fastener, 12"o.c. If Counter

Flashing or Reglet is used, seal to parapet wall with Tube Sealant.

8. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a

bead of Tube Sealant between the flashings and securing with Pop Rivets, 2.5"o.c.

Clip W/

1

/

4

"-14 x 1

1

/

2

" SD N/W

1

/

4

"-14 x

7

/

8

" Stitch XL (3 per panel)

SSR High Side Pitch Break

Back-up Channel

#12-14 x 1" SD N/W (see below)

Double Bead Tape Sealant

End Dam

Fastener (by others)

Magna-Loc Panel

8" MIN

2"

#12-14 x 1" SD NW

1

3

2

5

4

FASTENING PATTERN

1

/

2

:12 slope

Minimum

Advertising