Magna-loc, 20" ridge/hip cover – Metal Sales Magna-Loc Installation User Manual

Page 67

Advertising
background image

© Metal Sales Manufacturing Corporation / Subject to change without notice 6/12

67

MAGNA-LOC

20" rIdGe/HIp COVer

INstALLAtION NOtes

1. Once panels have been installed, slide Back-Up Channel under upper edge of panels. Position Back-Up Channel to allow

for proper installation of hip assembly. Use C-clamps to hold Back-Up Channel in place.

2. Apply a row of Double Bead Tape Sealant across panel, up and over all ribs approximately 2"-4" from panel end on both

sides of hip.

3. Install field cut Z-Closure over tape sealant. (See page 79 for preparing Z-Closures.) Before continuing make sure Z-

Closure placement will accommodate 20" Hip flashing.

4. Once Closure is set in Tape Sealant, fasten through Z-Closure, Tape Sealant, Magna-Loc panel, and into Back-Up Channel

with (5) #12-14 x 1" SD N/W per panel. C-clamps may be removed once Closures have been fastened.

5. Once all Z-Closures have been installed, place a row of Double Bead Tape Sealant across top of Closures on both sides of

hip. Tube Sealant must be used to fill any and all gaps left around Z-Closures.

6. Install 20" Hip flashing and secure to top leg of Z-Closure with ¼"-14 x

7

/

8

" Stitch XL at the spacing shown above.

7. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a

bead of Tube Sealant between the flashings and securing with Pop Rivets, 2.5"o.c.

Double Bead Tape Sealant

Clip W/ (2)

1

/

4

"-14 x 1

1

/

2

" SD N/W

20" Hip Cover

1

/

4

"-14 x

7

/

8

" Stitch XL (3 per panel)

Magna-Loc Panel (field cut)

Back-up Channel

Z-Closure (field cut)

#12-14 x 1" SD N/W (see below)

#12-14 x 1" SD NW

1

3

2

5

4

FASTENING PATTERN

1

/

2

:12 slope

Minimum

Advertising