Magna-loc, 180° panel profile – Metal Sales Magna-Loc Installation User Manual

Page 9

Advertising
background image

© Metal Sales Manufacturing Corporation / Subject to change without notice 6/12

9

MAGNA-LOC

4"

C

2"

Factory Applied Sealant

6"

6"

Factory Applied Sealant

16" Coverage (Flat)

2"

C

16" Coverage (Striated)

Factory Applied Sealant

2"

C

16" Coverage (Pencil Ribs)

Sellersburg and Fontana Branches Only

180

o

Seam

_ _ Represents color code designation.

See page 6 in this manual or Metal Sales color guides for color selection.

Requires additional lead time.

ACG

(Flat)

24 16"

2735741 130

ACG

(Striated)

24 16"

2735841 130

ACG

(Pencil Rib)

24

16"

2735541 130

PVDF

Standard(Flat)

24 16"

28357_ _

130

PVDF

Standard(Striated)

24 16"

28358_ _

130

PVDF

Standard(Pencil Rib)

24

16"

28355_ _

130

ACG

(Flat)

22 16"

2935741 161

ACG

(Striated)

22 16"

2935841 161

ACG

(Pencil Rib)

22

16"

2935541 161

PVDF

(Flat)

22 16"

30357_ _

161

PVDF

(Striated)

22 16"

30358_ _

161

PVDF

(Pencil Rib)

22

16"

30355_ _

161

ACG

(Flat)

24 18"

2735941 126

ACG

(Striated)

24 18"

2736041 126

ACG

(Pencil Rib)

24

18"

2735641 126

PVDF

Standard(Flat)

24 18"

28359_ _

126

PVDF

Standard(Striated)

24 18"

28360_ _

126

PVDF

Standard(Pencil Rib)

24

18"

28356_ _

126

ACG

(Flat)

22 18"

2935941 156

ACG

(Striated)

22 18"

2936041 156

ACG

(Pencil Rib)

22

18"

2935641 156

PVDF

(Flat)

22 18"

30359_ _

156

PVDF

(Striated)

22 18"

30360_ _

156

PVDF

(Pencil Rib)

22

18"

30356_ _

156

FINISH

GAUGE

COVERAGE

PRODUCT NO.

WT/SQ

PANEL NOTES

1. For panel lengths over 45'-0", please inquire.

2. Minimum recommended roof slope:

1

/

2

:12.

3. All panels have factory applied sealant.

4. Oil canning is not a cause for rejection. Heavier gauges help minimize oil canning.

5. The Magna-Loc panel system requires the use of a mechanical seamer for proper installation. Contact Metal Sales for rental

information.

6. If requested, panels are factory notched and/or pre-punched for endlap conditions.

7. Finish: PVDF (Meets Kynar 500/Hylar 5000 Specs).

8. For additional information on product applications, loadings and flashing details, consult the Product or Installation

Manuals.

180° PANEL PROFILE

Advertising