Magna-loc, Ssr sculpt. rake – Metal Sales Magna-Loc Installation User Manual

Page 60

Advertising
background image

© Metal Sales Manufacturing Corporation / Subject to change without notice 6/12

MAGNA-LOC

60

ssr sCuLpt. rAKe (

off

module

)

INstALLAtION NOtes

Magna-Loc Floating Rake Zee and Magna-Loc panels must be installed prior to SSR Sculptured Rake installation

(See Pages 43-53).

1. With Magna-Loc panel nested against Magna-Loc Floating Rake Zee, apply a row of Double Bead Tape sealant across

upper side of field bent panel rib. (See page 51 for proper bending of panel.)

2. Install SSR Rake Cleat over Double Bead Tape Sealant. Fasten through SSR Rake Cleat, Tape Sealant, panel, and into

Floating Rake Zee with #12-14 x 1

1

/

4

" Self Driller XL screws, 1'-0"o.c.

3. Apply a row of Double Bead Tape Sealant across top leg of SSR Rake Cleat.

4. Install SSR Sculptured Rake flashing so that top of flashing is flush with top of SSR Rake Cleat and panel rib. Fasten

through SSR Sculptured Rake, Tape Sealant, and into SSR Rake Cleat with ¼"-14 x

7

/

8

" Stitch XL, 1'-0"o.c.

5. Position and apply a row of Double Bead Tape Sealant across wall panel just below lower leg of SSR Rake flashing.

6. Install SSR Rake Slide over lower leg of SSR Rake flashing and Double Bead Tape Sealant. Fasten with ¼"-14 x

7

/

8

"

Stitch XL, 1'-0"o.c.

7. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a

bead of Tube Sealant between the flashings and securing with Pop Rivets, 2.5"o.c.

Magna-Loc Panel (field cut and bend)

Rake Angle (by others)

1

/

4

"-14 x

7

/

8

" Stitch XL (1'-0" o.c.)

SSR Sculptured Rake (off module)

Double Bead Tape Sealant
SSR Rake Cleat

Floating Rake Zee

#12-14 x 1

1

/

4

" SD XL (1'-0" o.c.)

1

/

4

"-14 x 1

1

/

4

" Shoulder SD (1'-0" o.c.)

SSR Rake Slide

1

/

4

"-14 x

7

/

8

" Stitch XL (1'-0" o.c.)

Double Bead Tape Sealant

2"

Closure (by others)

CAutION

Note: If panel does termi-

nate on module then Rake

Cleat is not needed.

1

/

2

:12 slope

Minimum

Advertising