MAINTENANCE AND TROUBLESHOOTING


6. Cooling Flow:







































































(A)

Check cooling flow

Adjusting Clamp open

(C)

Place Pump into a bucket of

water and check flow

(B)

Remove the Cooling Transfer

Tube from the Blade Guard inlet

(D)

Remove the Cooling Transfer

Tube and check flow

(E)

Remove the Pump Discharge

Fitting and check

(I)

Remove the Blade Guard

Intake Fitting

(H)

Remove the Pump Casing

and check for restriction;

check Impeller damage

(G)

Remove the 3 Pump Casing

Retaining Screws

(F)

Remove the Pump Intake

Screen and check for debris

Go to

Step C

Check Impeller

for damage

If flow exist,

go to Step E

If flow exist, go

to Step D

Pull Tab

to loosen

If flow exists,

go to Step A

Pull to

Remove

Cover Pump suction

with water

Pull to

Remove

If flow exist,

go to Step F

Remove

Discharge Fitting

Pull Intake Screen

to remove

If Screen clean,

go to Step G

Phillips

Screwdriver

Once Screws

removed, go

to Step H

Check for
restriction

If no damage

or restrictions,

go to Step I

Turn counter-

Clockwise

to loosen

Go to

Step J

Intake Fitting