MAINTENANCE AND TROUBLESHOOTING

°

7. Blade Stops Turning:




































































* A GFCI wall socket is the preferred protective device.

(D)

Verify the circuit breaker is at

least 20 amps – if not, move to

20-amp circuit

(A)

Allow motor to cool and

depress motor Overload

Reset Switch

(F)

Check power source voltage is

115V, if it is not 115v – move

to another circuit

(B)

Verify all plugs are fully

Installed*

(C)

Check to see if the Ground

Fault Circuit Interrupter (GFCI)

is tripped*

(E)

Verify circuit breaker is not

tripped, if it is tripped – reset the

circuit breaker once

Return to

MK Diamond

for Repair

(G)

Return to MK Diamond


If less than 20

Amps move saw

to 20 Amp circuit

Overload

Reset Switch

If motor does not

start, go to Step B

Verify all plugs

connected

If all plugs connected,

go to Step C

If not tripped, or

If a re-trip occurs,

Go to Step D

Reset once

if tripped

If circuit 20 Amp

or greater

go to Step E

Check Breaker

20 Amps

or greater

If tripped, reset

once if trips again,

go to step F

If circuit breaker

not tripped

go to Step F

Check Breaker

tripped

Check for

correct circuit

voltage

If voltage is

115V -

go to Step G