1 entering the service menu, 2 acsar identification, 1entering the service menu – Barco R9806700 User Manual

Page 70: 66 14.2acsar identification, Entering the service menu, Acsar identification, Acsar set ups, How to enter the service menu, How to enter the identification menu

Advertising
background image

14. ACSAR Set Ups

14.1 Entering the Service Menu

How to enter the Service menu

1. From the Adjustment mode menu, select item SERVICE. (menu 14-1)

The Service menu appears on-screen and in the graphical display. (menu 14-2)

2. To display the other items of the service mode, select item MORE and press ENTER or press selection wheel to confirm.

Second part of the service mode is displayed. The item MORE, allows to return to part 1 of the service menu. (menu 14-3)

ADJUSTMENT MODE

Select a path from below :

RANDOM ACCESS

INSTALLATION

SERVICE

Select with

or

then <ENTER>

<EXIT> to return

0HQX 

SERVICE

IDENTIFICATION

CHANGE PASSWORD
CHANGE LANGUAGE

CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION

MORE....

Select with

or

then <ENTER>

<EXIT> to return

0HQX 

SERVICE

BARCO LOGO

PRESET INPUT BALANCE

ADVANCED PROCESSING

DIAGNOSIS

MORE....

Select with

or

then <ENTER>

<EXIT> to return

0HQX 

Item PRESET INPUT BALANCE: this item is not active for reason that it belongs to a factory adjusted proce-
dure.

14.2 ACSAR Identification

How to enter the Identification menu

1. From the Service mode menu, select item IDENTIFICATION. (menu 14-4)

The Identification menu appears on-screen and in the graphical display. (menu 14-5)

The identification menu reveals the following info about the ACSAR:
-

Address of the ACSAR: adjustable, 0 up to 9 remotely accessible, or up to 255, PC accessible.

-

Installed software version.

-

Configuration set up: related to D-Cine Premiere which is always Front/Table, not adjustable.

-

Baudrate PC: transfer speed for communication with a PC, adjustable.

-

Present of a Network module.

-

Text: On Screen Display (OSD) enabled (ON) or disabled (OFF).

-

Serial number: fabrication number of the unit, useful when calling for technical assistance.

-

Run time: total run time since first start up.

2. Press EXIT (RCU) or select item RETURN with selection wheel on ACSAR to return.

SERVICE

IDENTIFICATION

CHANGE PASSWORD
CHANGE LANGUAGE

CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION

MORE....

Select with

or

then <ENTER>

<EXIT> to return

0HQX 

BARCO

*ACSAR*

ACSAR. Address:

001

Soft version:

1.0

Config:

FRONT/

TABLE

Baudrate PC: 115200
Network module:

NO

Text:ON

Serial No:

1234567

Run time:

100h

<EXIT> to return

0HQX 

66

R5976519 ACSAR 12122002

Advertising
This manual is related to the following products: