Connecting the dc power source – RKI Instruments 12 VDC Beacon 200 User Manual

Page 18

Advertising
background image

14 • 12 VDC Beacon 200 Operator’s Manual

The power converter, reset switch, and alarm buzzer are all factory wired.

WARNING: Make all connections to the 12 VDC Beacon 200 before

you connect the DC power source. Before you make any
wiring adjustments, always verify that all power sources
are not live.

Connecting the DC Power Source

Perform the following functions to connect the 12 VDC Beacon 200 to DC
power.

NOTE: Be sure to turn off the 12 VDC Beacon 200 before connecting or

disconnecting it from the 12 VDC power source.

1. Turn off, unplug, or disconnect all incoming power to the 12 VDC

Beacon 200.

2. Open the housing door, then place the power switch in the OFF

position.

P1

P2

CH1
OUT

+

BUZZER

NOT
USED

12 V
DC

+

RESET

CH2
OUT

+

RESET SWITCH

TB

1

RESET

BUZ +

BUZ

Power

Converter

MAIN PCB

Figure 6. 12 VDC Beacon 200 Factory Wiring Diagram

Advertising