Beacon 200 Rig Monitor Operator’s Manual • 18

bushing.

4. Guide the wiring of the external alarm device through the new conduit

hub on the bottom of the Rig Monitor housing.

5. Connect the leads from the external alarm device and power to the

alarm terminals as shown in Figure 9.

6. Repeat steps 4 and 5 for additional external alarm devices.

Connecting a Recorder

Perform the following procedure to connect an analog recording device to
the Rig Monitor. The output at the recorder output terminals is a 4 - 20 mA
signal that is proportional to the detection range of the applicable detector
head.

1. Disconnect the battery clamps from the + and - terminals of the 12

VDC battery.

2. Open the housing door, then place the power switch in the OFF

position. Locate the recorder output terminals on the controller terminal
strip (see Figure 1).

3. Install an appropriately rated cable bushing in the Rig Monitor housing.

All factory supplied conduit hubs are used in the Rig Monitor, so you
will need to drill a hole in the housing for a conduit hub and cable
bushing.

4. Guide the wiring from the recording device through the new conduit

hub on the Rig Monitor.

Beacon 200 Alarm
Terminal Strip

- (N)

+ (H)

CH1-A1

NO NC

C

External Alarm

Device

External Power

Source

Figure 9. Typical External Alarm Wiring