Replacing components of the rig monitor – RKI Instruments Beacon 200 RIg Monitor, H2S/H2S User Manual

Page 44

Advertising
background image

39 • Beacon 200 Rig Monitor Operator’s Manual

factory setting is 2.

7. Turn the Audio Select switch so that the selection arrow is pointing to

the desired number.

8. Place the cover over the base and push in and down in order to

reinstall the cover. Make sure that the cover is sealed to the base by
the gasket.

9. Screw the captive screw at the bottom front of the strobe/horn back in.

Replacing Components of the
Rig Monitor

This section describes how to replace the fuses, the plug-in H

2

S sensor,

and the entire H

2

S detector.

Replacing the Fuses

1. Open the housing door of the Rig Monitor, then place the power switch

in the OFF position.

2. Disconnect the battery clamps from the + and - terminals of the 12

VDC battery.

3. Locate the vertical fuse holders on either side of the power switch. The

DC fuses are labelled F2 and F3 and are on the right of the power
switch.

4. Use a flat-blade screwdriver to rotate the applicable fuse holder 1/4

turn counterclockwise. The fuse holder releases from the socket.

5. Remove the fuse holder from the socket, then remove the fuse from

the fuse holder.

CAUTION: Verify that the replacement fuse is the same type and rating as

the fuse you are replacing.

6. Install the appropriate replacement fuse in the fuse holder, then place

the fuse holder in the socket.

7. Push the fuse holder into the socket, then turn the holder 1/4 turn

clockwise to secure it in the socket.

8. Connect the battery clamps to the + and - terminals of the 12 VDC

battery.

9. Place the Rig Monitor’s power switch in the ON position, then verify

that the PILOT light is on.

Advertising