Figure 12. top case removal, Figure 13. strobe/horn cover – RKI Instruments Beacon 200 RIg Monitor, H2S/H2S User Manual
Page 43
Advertising

Beacon 200 Rig Monitor Operator’s Manual • 38
4. Grasp the top and bottom of the strobe/horn and push up and out in
order to remove the cover.
5. Turn the cover over and locate the Audio Select switch at the top of the
cover as shown in the figure below.
6. The Audio Select switch can be set at any number between 1 and 6.
Numbers 1-3 all produce an intermittent buzzing sound with 1 being
the loudest and 3 being the quietest. Numbers 4-6 all produce a steady
buzzing sound with 4 being the loudest and 6 being the quietest. The
Push Up Here
Captive
Screw
Push Out
Top
Base
Figure 12. Top Case Removal
Audio Select Switch
AUDIO
SELECT
6
Strobe Brightness Switch
(DO NOT ADJUST)
1
2
3
4 5
CANDELLA S ELECT
Figure 13. Strobe/Horn Cover
Advertising