Magnetic Wand

The magnetic wand is a short plastic rod with a magnet in one end. It is used to actuate
the magnetic control switches on the control PCB while the junction box cover is still
installed so that non-intrusive calibration can be performed.

Gas Detector

The gas detector senses the target gas and is mounted in a 3/4” conduit hub on the right
bottom side of the M2. A variety of detectors may be used with the M2. Table 2 below lists
the detectors that can be used with the M2.

Table 2: M2 Detectors

Target Gas, Range

Detector(s) Used

Combustible Gas, 0 - 100% LEL

61-0140RK (Catalytic UL version)

61-0140RK-05 (Catalytic CSA version)

Hydrogen, 0 - 100% LEL

NC-6205-01 (Catalytic UL version, hydrogen specific)

NC-6205-05 (Catalytic CSA version, hydrogen specific)

CH

4

, 0 - 100% LEL

61-0190RK-CH4 (IR UL)

HC, 0 - 100% LEL (cal. to propane)

61-0190RK-HC (IR UL)

CH

4

, 0 - 100% volume

61-0192RK-CH4 (IR UL)

CO

2

, 0 - 5,000 ppm

61-0191RK-02 (IR UL)

61-0198RK-02 (IR)

CO

2

, 0 - 5%

61-0191RK-03 (IR UL)

61-0198RK-03 (IR)

CO

2

, 0 - 50%

61-0191RK-05 (IR UL)

61-0198RK-05 (IR)

CO

2

, 0 - 100%

61-0191RK-10 (IR UL)

61-0198RK-10 (IR)

Oxygen, 0 - 25%

65-2494RK (capillary)

65-2510RK (partial pressure)

65-2511RK (capillary)

65-2514RK (capillary, CSA)

CO, 0 - 300 ppm

65-2433RK-05 (CSA)

65-2496RK

H

2

S, 0 - 100 ppm

65-2423RK-05 (CSA)

65-2495RK

NH

3

, 0 - 75 ppm

65-2300RK-NH3

AsH

3

, 0 - 1.5 ppm

65-2300RK-ASH3

Cl

2

, 0 - 3 ppm

65-2300RK-CL2

Cl

2

, 0 - 10 ppm

65-2300RK-CL-10

PH

3

, 0 - 1 ppm

65-2300RK-PH3

Advertising