Wiring the m2 rig monitor, M2 rig monitor operator’s manual 12 – RKI Instruments M2 Rig Monitor User Manual

Page 17

Advertising
background image

M2 Rig Monitor Operator’s Manual

12

Wiring the M2 Rig Monitor

WARNING:

Always verify that the power source is OFF before making any wiring
connections.

The detector leads, junction box connection, power cable wiring, and strobe/horn wiring
are all factory wired as shown in the figure below.

Figure 8: Rig Monitor Factory Wiring

Strobe/Horn

S

T

O

X

IC

O

X

Y

PW

R

/S

IG

C

NC

NO

C

NC

NO

FA

IL

Not

Used

AL

AR

M

1

4-20 mA

out (S)

Power Converter

White

Red

Black

Black

White

Black

Black

Detector Cable

Terminal PCB

H2S Detector

Battery Cable

RS

485

A

B

C

C

N

C

N

O

AL

AR

M

2

Red

Chassis Ground

Black

Blue

Red

To 12 V

Battery Terninals

Advertising