Adjusting strobe/horn volume – RKI Instruments M2 Rig Monitor User Manual

Page 36

Advertising
background image

31

M2 Rig Monitor Operator’s Manual

Adjusting Strobe/Horn Volume

The horn volume on the strobe/horn can be adjusted by doing the following:

1.

Disconnect the battery clamps from the + and - terminals of the 12 VDC battery.

2.

Loosen the captive screw at the bottom front of the strobe/horn.

3.

Grasp the top and bottom of the strobe/horn and push up and out in order to remove
the cover.

Figure 10: Top Case Removal

4.

Turn the cover over and locate the Audio Select switch at the top of the cover as
shown in the figure below.

Figure 11: Strobe/Horn Cover

5.

The Audio Select switch can be set at any number between 1 and 6. Numbers 1-3 all
produce an intermittent buzzing sound with 1 being the loudest and 3 being the
quietest. Numbers 4-6 all produce a steady buzzing sound with 4 being the loudest
and 6 being the quietest. The factory setting is 2.

Push Up Here

Captive

Screw

Push Out

Top

Base

Audio Select Switch

AUDIO
SELECT

6

Strobe Brightness Switch
(DO NOT ADJUST)

1

2

3

4 5

CANDELLA S ELECT

Advertising