7−6.List of recommendable spare parts

for regular maintenance

No.

Name of parts

Maintenance

interval

Replacement
Interval(year)

Q’ty/unit

1

Pump (without diaphragm)

6 months

1∼3

1

2 Pump

diaphragm

6 months

1∼2

1

3 Pump

holder

1year

3∼6

1

4 Fuse

1 year

8 1

5 Main

PCB

−−−

7∼8

1

6 Sub

PCB

−−−

9∼10

1

7

Internal tubing (Rubber)

6 months

3∼6

1

8

O-ring(Connection ports of
sensor unit and chassis
unit)

1 year

3∼6

4

9 Lithium

battery

−−−

3 1

10 Flowmonitor

ass’y

1 year

7∼8

1

11 O-ring (Flowmonitor part)

1 year

3∼6

2

12 Dust filter (Outside use)

6 months 0.5∼1

1

* The above replacement interval is just a standard and it depends upon operating

conditions. Also, this does not show a guarantee period.
Replacement interval changes according to the result of regular maintenance check..

* PCB is caused by deterioration of capacitor, etc.
* Use pre-adjusted PCB when it is required to replace.

* Note