6-8

Viewing the Adapter’s Web Pages

20-COMM-M Modbus/TCP Adapter User Manual
Publication 20COMM-UM014C-EN-P

Figure 6.6

DOS Window Showing E-mail Server IP Address

The IP address shown in the DOS window (for this example,
131.200.78.4) should be typed into the E-mail Notification Web
Page shown in

Figure 6.4

.

3. Click Save changes.

Important: After configuring E-mail Notification, it is recommended to

protect the settings. Otherwise the configuration can be
changed anytime the web page is accessed with a browser. To
protect the settings, use Parameter 37 - [Web Features] to set
E-mail Cfg Bit 0 value to “0” (Disabled).

Figure 6.7

shows an example e-mail message automatically sent by the

adapter in response to selected events.

Figure 6.7

Example of E-mail Message Sent by Adapter

TIP: To stop e-mail messages, uncheck all of the “Send an e-mail message
when…” boxes.

Disabling the adapter web pages by setting the Web Pages Switch (SW2 in

Figure 2.1

) to the “Disable Web” position will NOT stop the adapter from

sending e-mail messages.