B-2

Adapter Parameters

20-COMM-M Modbus/TCP Adapter User Manual
Publication 20COMM-UM014C-EN-P

08
09
10
11

[Subnet Cfg 1]
[Subnet Cfg 2]
[Subnet Cfg 3]
[Subnet Cfg 4]

Sets the bytes of the subnet mask.

Important: To set the subnet mask using these
parameters, Parameter 03 - [BOOTP] must be set to
“0” (Disabled).

Default:

0

Default:

0

Default:

0

Default:

0

Minimum:

0

Maximum:

255

Type:

Read/Write

Reset Required: Yes

12
13
14
15

[Gateway Cfg 1]
[Gateway Cfg 2]
[Gateway Cfg 3]
[Gateway Cfg 4]

Sets the bytes of the gateway address.

Important: To set the gateway address using these
parameters, Parameter 03 - [BOOTP] must be set to
“0” (Disabled).

Default:

0

Default:

0

Default:

0

Default:

0

Minimum:

0

Maximum:

255

Type:

Read/Write

Reset Required: Yes

16 [EN Rate Cfg]

Sets the network data rate at which the adapter
communicates. (Updates Parameter 17 - [EN Rate
Act]
after a reset.)

Default:

0 = Autodetect

Values:

0 = Autodetect
1 = 10 Mbps Full
2 = 10 Mbps Half
3 = 100 Mbps Full
4 = 100 Mbps Half

Type:

Read/Write

Reset Required: Yes

17 [EN Rate Act]

Displays the network data rate actually used by the
adapter.

Default:

0 = No Link

Values:

0 = No Link
1 = 10 Mbps Full
2 = 10 Mbps Half
3 = 100 Mbps Full
4 = 100 Mbps Half

Type:

Read Only

18 [Modbus/TCP Port]

Sets the TCP port used to transport Modbus/TCP
messages.

Default:

502

Minimum:

0

Maximum:

65535

Type:

Read/Write

Reset Required: Yes

Parameter
No. Name and Description

Details

255 . 255 . 255 . 255

[Subnet Cfg 1]

[Subnet Cfg 2]

[Subnet Cfg 3]

[Subnet Cfg 4]

255 . 255 . 255 . 255

[Gateway Cfg 1]

[Gateway Cfg 2]

[Gateway Cfg 3]

[Gateway Cfg 4]