Main control panel, Remove components – Rockwell Automation 20B PowerFlex 700 Drive Components Replacement - Frame 8 User Manual

Page 24

Advertising
background image

24

Rockwell Automation Publication 20B-IN024C-EN-P - June 2012

Chapter 2

Basic Component Removal Procedures

Main Control Panel

See

Chapter 1 - Component Diagrams and Torque Specifications

to locate the

component detailed in these instructions.

Remove Components

1. Read and follow the

Safety Precautions on page 12

and

Important Initial

Steps on page 13

.

2. Remove the ribbon cable going from the main control board (J2) to the

power interface board ( J1).

3. Disconnect the incoming ground wire to TB11.
4. Remove the two screws on the main control panel below TB11.
5. Remove the two mounting nuts at the top of the main control panel.

6. Disconnect the wire harnesses from TB11 to the switch mode power

supply board ( J4 connector) and at TB1 and TB2 on the power interface
board.

7. Label and remove all customer wiring from TB11.
8. Remove the main control panel and carefully set aside.

Ribbon
Cable

Mounting Nuts (2) at top
of Main Control Panel

Ground Wire
to TB11

MCP Mounting Screws (2) below TB11

Mounting Nuts (2) at top
of Main Control Panel

Ground Wire
to TB11

MCP Mounting Screws (2) below TB11

Mounting Nuts (2) at top
of Main Control Panel

Ground Wire
to TB11

Main Control Panel Mounting Screws (2) below TB11

Advertising