Basic Component Removal Procedures Chapter 2

6. Remove all IGBT Snubber components:

a. Remove the six nuts that secure each set of snubber capacitors. Remove

the capacitors, and save nuts and capacitors.

b. Remove the two screws that secure each tie down capacitor mount.

Remove the tie down capacitor mounts and save screws and capacitor
mounts.

c. Remove the six setscrews from each IGBT and save.

If replacing an IGBT module, remove the nuts and DC– flexible capacitor
busbars, and save nuts and busbars.

7. Cut tie wraps for the balancing resistor wiring.

Snubber
Capacitors

Snubber

Capacitor

Mount Nuts

Tie Down

Capacitor

Mount

Screw

Tie Down

Capacitor

Mount

Screw

Nuts for

DC– Flexible

Capacitor

Busbars

Setscrews