Install components – Rockwell Automation 20B PowerFlex 700 Drive Components Replacement - Frame 8 User Manual

Page 46

Advertising
background image

46

Rockwell Automation Publication 20B-IN024C-EN-P - June 2012

Chapter 3

Component Replacement Procedures

Install Components

1. Use a 3 mm angle hex wrench to replace the setscrews for each new

capacitor. Torque to 0.7 N•m (6 lb•in).

2. Place capacitors into correct position in drive (vent plug at top or 12

o’clock).

3. Place bus capacitor busbar onto capacitors.
4. Install the 18 washers and nuts onto setscrews, but do not tighten yet.
5. Place the transitional busbar in position. Make sure that all setscrews,

washers, and nuts fit. Adjust as needed.

6. Remove the transitional busbar, and tighten all washers and nuts for the

bus capacitor busbar. Torque to 5.6 N•m (50 lb•in).

7. Install the transitional busbar assembly as detailed on

page 32

.

8. Replace all safety shields and enclosure covers before applying power to the

drive.

ATTENTION:

Install each capacitor so its vent plug is at the

top

or 12 o’clock. Component and system damage may result if

you position any bus capacitor incorrectly.

IMPORTANT

Each capacitor needs a short and long setscrew. See the illustration
below for where to install each setscrew.

Capacitors shown

with Bus Capacitor

Busbar installed

Vent Plug (must be at
top

or 12 o’clock)

Longer Setscrew

for Transitional

Busbar

Shorter Setscrew

for Bus Capacitor

Busbar

Advertising