Using 160-DN2 with DeviceNet Scanner

Using Explicit Messaging
(Continued)

ControlLogix Example

Data Format for a Read and Write Parameter

The data in this example is for a Bulletin 160-SSC drive at MAC ID
1.

For a description of the content in each box, refer to the “

Formatting

Explicit Messages

” subsection starting on

Page 6-23

.

Figure 6.21
ParameterReadMessage Screen

Box

Setting

Description

Refer to . . .

Message Type
Service Type
Class
Instance
Attribute
Destination

CIP Generic
Get Attribute Single
B3 (hex)
1 (dec)
3 (hex)

Must be CIP Generic
Defines Service Code as text message
160 Parameter Table Object
Number of Instances
Parameter Number

User-created tag for parameter data

6-25
6-25
B-18
B-18
B-18
6-25

For this example screen, Parameter 3 - [Output Current] was selected.

For this example screen, the tag Output_Current was created and assigned. To create a
tag, click New Tag, enter tag name, select Data Type, and click OK. To assign this tag,
click on the Destination dropdown arrow, select the defined tag, and click outside the
dropdown list.