Class code 0x0f - parameter object, Class code 0x0f — parameter object – Rockwell Automation 160-DN2 160-DN2 DeviceNet Communication Module FRN 3.xx User Manual

Page 91

Advertising
background image

Publication 0160-5.18 - June 2003

DeviceNet Information

B-9

Class Code 0x0F —
Parameter Object

Class Attributes

Number of Instances: 118

Instance 1 through 118 Attributes

Value varies based on parameter instance.

Attribute ID

Access Rule

Name

Data Type

Value

1

Get

Revision

UINT

1

2

Get

Max Instance

UINT

118

8

Get

Parameter Class Descriptor

WORD

0x0B

9

Get

Configuration Assembly Instance

UINT

190

10

Get

Native Language

USINT

0 = English

Attribute ID

Access Rule

Name

Data Type

Value

1

Set

Parameter Value

data type specified in
Descriptor, Data Type and
Data Size

2

Get

Link Path Size

USINT

3 Get

Link Path

Segment type/port

Segment Address

ARRAY of DeviceNet path

BYTE

path

6

“20 B3 24 01 30 01”

4 Get

Descriptor

WORD

5 Get

Data

Type

USINT

6

Get

Data Size

USINT

7

Get

Parameter Name String

SHORT_STRING

8

Get

Units String

SHORT_STRING

9

Get

Help String

SHORT_STRING

10

Get

Minimum Value

data type

11

Get

Maximum Value

data type

12

Get

Default Value

data type

13

Get

Scaling Multiplier

UINT

14

Get

Scaling Divisor

UINT

15

Get

Scaling Base

UINT

16

Get

Scaling Offset

INT

17

Get

Multiplier Link

UINT