Table 4 - Meaning of the diagnostics LEDs

Display

Meaning

G 1

G 2

G 3

G 4

Power-up sequence: After switching on the SC300
and after each teach-in, the power up sequence runs. Starting with the diagnostics LED 1, the next
diagnostics LED illuminates after one second and so on until all 4 diagnostics LEDs are illuminated.

Protective field sector free

G

Interruption of the protective field in the allocated protective field sector (see Figure 8). A protective
field sector represents one quarter of the field of view of the SC300.

Teach-in mode (see “Teach-In” on page 40).

Warning (see “Fault Diagnosis” on page 45).

Error (see “Fault Diagnosis” on page 45).