Table 15 - Data sheet SC300

Minimum

Typical

Maximum

General system data

Protective field dimensions

See “Checking the dimensions of the protective field” on page 15.

Type

SC300 safety camera

3 (EN 61

496­1, IEC/TR 61 496­4)

Safety integrity level

–

SC300 safety camera

SIL2 (IEC 61 508), SILCL2 (EN 62 061)

Category

SC300 safety camera

3 (EN ISO 13

849­1)

Performance Level (Safety integrity level)

SC300 safety camera

PL d (EN ISO 13

849­1)

Test rate

50 ¹/

s

(EN ISO 13

849­1)

Demand rate

—

30 ¹/

min

(EN ISO 13

849­1)

PFHd (mean probability of a dangerous
failure per hour)

3.2 × 10

–9

T

M

(mission time)

20 years (EN ISO 13

849)

Protection class

III (EN 50

178)

Enclosure rating

IP 54 (EN 60

529)

Resolution

20 mm, 24 mm or 30 mm

Field of view

103° ± 3°

Ambient operating temperature

0 °C

+50 °C

Storage temperature

–25 °C

+70 °C (

≤24 h)

Humidity, taking into account the
operating temperature range

EN 61

496­1, section 5.1.2 and section 5.4.2 as well as IEC/TR 61 496­4,

section 5.4.2

Air humidity (non-dewing)

15

%

95

%

Sinusoidal vibration

5 g, 10–55 Hz (EN 60

068­2­6)

Shock resistance

10 g, 16 ms (EN 60

068­2­27)

Lighting

Wavelength

850 nm

Occular safety

Photobiologically harmless (IEC 62

471­7)