Rockwell Automation 442L SC300 Safety Sensor User Manual User Manual
Page 35

Rockwell Automation Publication 10000202762 Ver 00 - January 2012
33
Chapter 5
Electrical installation
Figure 27 - Two SC300 safety cameras with external teach connected to a GSR DI safety relay
module with configured for monitored manual restart
Principle of operation
When the light path on both SC300 safety cameras are clear and the input conditions on
the GSR DI safety relay modules are valid, the system is ready for switch on and waits for
an input signal/switch on signal. The system’s corresponding logic path is enabled by
pressing and releasing the related restart switch. The related outputs of the GSR DI carry
power. If the input conditions are no longer met, the related outputs of the GSR DI shut
down.
Power
In1
In2
Out
Logic
A2
A1
+
-
S11
S21
S12
S22
S32
S42
L12
L11
Y32
S34
13
14
23
24
24VDC
IN1
DI
IN2
0 1
2
3
4
5
6
7
8
LOGIC
Test Out
Teach
Camera Pigtail
889D-F8AB-X
Wht
Yel
Blu
Red
Gry
Brn
Grn
Pnk
Teach
Camera Pigtail
889D-F8AB-X
Wht
Yel
Blu
Red
Gry
Brn
Grn
Pnk
Restart
K1
K2
L1 L2 L3
M
Wht 1 Reset
Color Pin Signal
Brn 2 +24V
Grn 3 Teach
Yel 4 EDM
Gry 5 OSSD 1
Pnk 6 OSSD 2
Blu 7 0V DC
Red 8 FE
K1
K2
24V DC
0V DC