Chapter 11

Technical specifications

–

To meet the requirements of the relevant product standards (e.g., EN 61 496-1), the external voltage supply for
the devices (SELV) must be able to bridge a brief mains failure of 20 ms. Power supplies according to EN 60 204-
1 satisfy this requirement. Suitable power supplies are available as accessories from Rockwell Automation (see
“Accessories” on page 53).

—

Within the limits of V

s

.

Table 15 - Data sheet SC300

Minimum

Typical

Maximum

Housing

Material

Aluminium die-cast

Dimensions

See “Dimensional drawings” on page 50.

Total weight

0.355 kg

Reflective tape (length × width)
for resolution:

20 mm

1.00 m × 37 mm

24 mm

1.20 m × 37 mm

30 mm

1.50 m × 48 mm

Power-up delay after connecting the
supply voltage

6 s

Electrical data

Supply voltage V

s

at the device (SELV)

– 19.2V

24V

28.8V

Permissible cable resistance on the supply
cable

1

Ω

Residual ripple

—

Operating current

at 24V without output load

165 mA

with maximum output load

690 mA

Power consumption

at 24V without output load

4 W

with maximum output load

19 W

Electrical connection

M12

× 8 (see “System connection” on page 28)

Cable length for wire cross-section
0.25 mm²

7.5 m

Synchronization

Electrical (see “System connection” on page 28)

External device monitoring (EDM) input

Resistance HIGH

2 k

Ω

Capacitance

15 nF

Voltage (IEC 61

131­2)

HIGH

11 V

24 V

30 V

LOW

–3 V

0 V

5 V

Static current

6 mA

15 mA