Fault diagnosis

Table 14 - Indications on completion of the teach-in

Status LEDs Diagnostics LEDs

Meaning

Rectification of the error

1

2

3

4

G

Warning

Short-circuit or
overcurrent on
an OSSD

Check the contactor. Replace, if necessary.
Check the wiring for short-circuits or cross-
circuits.

G

Error

G

Warning

External device
monitoring

Check the contactors and their wiring,
eliminate any wiring errors, if necessary.
Switch the device off and back on again. Check
the configuration of the external device
monitoring (see page 12).

G

Error

G

Warning

Reset button

Check the reset button for correct function. The
button may be defective or stuck.
Check the wiring of the reset button for any
short-circuit to 24V.

G

Error

G

Warning

TEACH input

Check the connection of the external key-
operated pushbutton for teach-in.

G

Error

G

Error

System error

Disconnect the supply voltage to the SC300 for
at least 3 seconds.
If the problem persists, replace the unit.